Danfoss controls for use in hazardous areas
In Ex areas, where people’s lives and high-value materials are at stake, safety, robustness and reliability requirements leave no room for compromise.
By working in partnership with Danfoss Industrial Automation, you can be confident that you will get precisely the controls needed to achieve optimum safety.
Our comprehensive range of intrinsically safe solenoid valves, switches, pressure transmitters and temperature sensors is designed and approved to be used in environments where there is a danger of explosion. Our products cover countless applications within the heating, marine & engine, hydraulic and vacuum industries. Solenoid Valves
Danfoss solenoid valves are designed for explosion-risk environments; i.e., where flammable liquids and gasses are produced, transported or tapped. They are delivered as a part programme, with a separate valve and coil, and can be quickly and simply assembled without tools, providing optimum product flexibility and availability.
Approved for use in Zone 1 in accordance with directive 94/9/EC (ATEX 100A) EN50014 and EN50028.
Coils for Solenoid Valves
Suitable Valve Body for Eex appropved coils: (see data sheets for further details)
Direct-operated: 2/2-ways: EV210B DN 1.5 - 25B, EV210B DN 1.5 - 3SS, EV212B DN 1.5 - 3SS, 3/2 way: EV310B DN 1.5 - 2B
Servo-operated: 2/2-ways: EV220B DN 6 - 22B/DN 6 - 22BD, EV220B DN15 - 50B/DN 65 - 100C, EV220B DN 6 - 50B/DN 15 - 50SS, EV222B DN 15 - 50,
EV250B DN 12 - 22B
Power consumption holding Coil type Supply voltage Code No.
10W 21 VA BO024C 24V50/60 Hz 018Z6595
10W 21 VA BO048C 48V50/60 Hz 018Z6594
10W 21 VA BO110C 110V50/60 Hz 018Z6593
10W 21 VA BO230C 230V50/60 Hz 018Z6592
10W 21 VA BO240C 240V50/60 Hz 018Z6591
11W BO024D 24 dc with 5 m cable 018Z6596
16W BP024D 24 dc with 3 m cable 018Z6633 (Obsolete)
Switches
The Danfoss RT-E series, pressure, differential pressure and temperature switches, are designated for industrial refrigeration and general industrial application in explosive zones.
The range includes solutions for refrigeration systems with ammonia, hydrocarbons and other applications where flammable gases, vapours, mists and dust are likely to occur.
RT-E pressure and temperature switches for use in explosive zones incorporate an SPDT changeover switch, where contact position depends on the pressure or temperature values of the system.
Approved in accordance with 94/9/EC, ATEX directive, explosive
zone 1, for surface equipment, category 2.
Pressure Switches (as standard connection G3/8A and with auto reset)
Type Range Differential Max W/P Reset Code No
Bar Bar Bar G3/8+ G3/8
Weld nipple
RT112E 0.1 to 1.1 0.007 to 0.16 7 Auto 017-518566
RT113E 0 to 0.3 0.001 to 0.05 0.4 Auto 017-519566
RT1AE -0 .8 to 5 0.5 to 1.6 22 Auto 017-500966
RT116E 1 to 10 0.3 to 1.3 22 Auto 017-520166
RT5E 4 to 17 1.2 to 4 22 Auto 017-525266
RT6AEW 5 to 25 Fixed 3 34 Auto 017-513866
RT6AEB 10 to 28 Fixed 1.5 34 Man 017-513466
RT6AES 10 to 28 Fixed 1.5 34 Man 017-502166
RT117E 10 to 30 1 to 4 42 Auto 017-529866
Differential Pressure Switches (as standard connection G3/8A and with welded nipple Ø6.5/10 mm)
Type Range Differential Max. working pressure Code no:
RT 260AE 0.5 to 4 bar fixed 0.3 bar 22 bar 017D003666
RT 262AE 0.1 to 1.5 bar fixed 0.1 bar 11 bar 017D003066
RTe Temperature Switches (as standard with 2 m capillary tube)
Type Range Type of charge Max. sensor temp. Code no:
RT 14E -5-30 °C B 150 °C 017-509866
RT 101E 25-90 °C B 300 °C 017-512666
RT 107E 70-150 °C C 215 °C 017-515366
RT 123E 150-250 °C C 300 °C 017-521666
Type of charge: B = Adsorption, C = Partial
Pressure Transmitters
The Danfoss Eex pressure transmitter programme offers reliable pressure measurement, even in harsh and demanding applications. It covers a 4-20 mA output signal, absolute and gauge (relative) versions, measuring ranges from 0-1 to 0-600 bar, and zero point and span adjustment with a wide range of pressure connections.
Some models are also available with integrated pulse snubber for protection against cavitation, liquid hammer or pressure peaks.
Approval
EEx ia IIC T6 explosion protected in accordance with ATEX 100a.
Pressure Transmitters (as standard with span/zero adjustment, connection G1/2A, 4 - 20 mA output signal and with Pg9 electrical plug)
Type Measuring range Pe (bar) Comments Code no.
MBS4701 0-1 bar 060G4303
MBS4701 0-1.6 bar 060G4300
MBS4701 0-2.5 bar 060G4304
MBS4701 0-4 bar 060G4305
MBS4701 0-6 bar 060G4306
MBS4701 0-10 bar 060G4307
MBS4701 0-16 bar 060G4301
MBS4701 0-25 bar 060G4308
MBS4701 0-40 bar 060G4309
MBS4701 0-60 bar 060G4302
MBS4701 0-100 bar 060G4310
MBS4751 0-160 bar with pulse-snubber 060G4311
MBS4751 0-250 bar with pulse-snubber 060G4312
MBS4751 0-400 bar with pulse-snubber 060G4313
MBS4751 0-600 bar with pulse-snubber 060G4314
Temperature sensors and transmitters
Danfoss temperature sensors are designed for heavy-duty applications and are based upon decades of global experience within the marine industry and in refrigeration plants - among the toughest environments.
The range includes different versions with measuring ranges from -50°C to 800°C.
MBT 5113 and MBT 5116 for measuring and regulating exhaust gas in stationary and marine equipment like diesel engines, turbines and compressors, among others.
MBT 5250 and MBT 5252 for measuring and regulating temperature in piping systems and refrigeration plant on ships – or at all points where reliable, robust and accurate equipment is required.
These temperature sensors include Pt-sensing elements which are passive components and therefore classified as a simple apparatus. As such they cannot be approved according to the ATEX directive.
Approvals
Temperature transmitter MBT 9110, EEx approval:
KEMA 03ATEX1339 X II 1 G D, T80°C T105°C
EEx ia IIC T6 / T4
Max. amb. temperature for T1...T4 85°C
Max. amb. temperature for T5 and T6 60°C
ATEX, applicable in zone 0, 1, 2, 20, 21 or 22
The EEx approved transmitter can be used together with our temperature sensors if certain measures are taken.
Eex installation
For safe installation of MBT 9110 transmitters in hazardous areas, the following points must be observed:
- The module must only be installed by qualified personnel who are familiar with national and international laws, directives and standards that apply.
- The transmitter is approved to be mounted in a metal enclosure Form B according to DIN 43729 that is providing a degree of ingress protection of at least IP 6X in accordance with EN 60529.
- The ATEX transmitter can be mounted in the standard B-head or in a heightened lid, but only the transmitter is ATEX approved and marked according to this.
For further information on above products - see data sheets
--------------------------------------------------------------------------------------------------------------------------